2024/02/15 Sky Prog Programmer software Version 01.17 This version was uploaded to the server on 12/20/2023. 1. The most basic change is the improvement of the firmware recording function in Candy Invensys PCB. Previously, in FT_MODE=1 mode, the software froze on some boards of this type. Now this point has been corrected. 2. The ability to work in EP program mode with new SW has been introduced (01.02.06, 01.35.01, 00.35.15, 02.08.02, 11.00.10, 11.00.08) 3. The built-in INDESIT firmware database contains 13586 firmwares. 2022/06/01 Sky Prog Programmer software Version 01.16 1. Significantly expanded built-in help. Added an additional description of the various functions of the software, added a lot of images with connections, manufacturing accessories, parsing error statistics and deciphering errors for various products (ovens, dishwashers). Built-in help is opened by pressing the F1 key from the main software window, and is also duplicated on the program website. 2. Fixed a bug when reprogramming the refrigerator module with SW 11.00.11 in EP mode. 3. Minor changes and additions have been made that practically do not affect the functionality of the program. 4. The built-in INDESIT firmware database contains 13077 firmwares. 2022/04/20 Sky Prog Programmer software Version 01.15 1. Updated CANDY MEM firmware database. Instead of the base from 11/25/2019, now the base is from 09/02/2021. At the moment, this is the latest base from the manufacturer. 2. Added support for 12-digit serial numbers in firmware for PCB of the ARCADIA 1 and newer series. 3. Added display of error statistics, including the last error, for HOTTIMA oven PCB, SW 03.00.10 и 03.01.10. Later, a decryption of errors will be added to the help of the program. 4. S19 files with missing (blank) areas are now allowed to open in the program. The modal window that pops up is now a warning instead of a prohibition like it used to be. Skipped zones will be padded with 0xFF bytes. 5. A new mode of data exchange with the FT232RL chip has been introduced. It was already in the previous version of the software, but only in testing mode and was not used. Now this mode is set by default. It can always be changed in the settings to the old mode by setting FT_MODE=0. It was necessary to make a new mode because of new batches of converters based on this microcircuit from China. Half of them stopped working correctly in bit-bang mode according to the previous scheme (no response, which leads to slowdown when reading / writing). 6. The BACK button is built into the INDESIT firmware database. If you came to the database from the firmware selection help table, then by clicking on this button you will return back to the table with the last search query. 7. The firmware selection help table (opening by pressing F2 from the main program window) is now based on the virtual list library. This allows you to quickly work with a large number of records in the table when searching for the desired product model. 8. Changed/fixed some minor points that do not affect the functionality of the software. 9. The built-in INDESIT firmware database contains 13056 firmwares. 2021/01/31 Sky Prog Programmer software Version 01.14 1. Added new firmwares to the SW database for working with the function USBDM: 01.03.02; 01.03.09 ARTICA; 11.00.11. At the moment, the following SW included in the database: 01.04.02, 01.04.03, 01.04.09, 01.04.13. 01.03.09, 02.00.10, 02.06.02, 03.06.00, 03.06.05, 03.08.08, 01.03.02, 01.03.09 ARTICA, 11.00.11 (13 pcs). 2. Added support for the RENESAS R5F51115ADFM microcontroller (used in dishwashers, WINDY platform) to the RS function. 3. Added new FW/SW to work with RS function: 25.00.16; 11.01.00; 33.00.06; 35.00.05; 35.00.10; 36.00.06; 33.01.00; 05.02.06; 05.02.16; 05.02.18; 06.00.00. At the moment, the following SW included in the software: 11.01.13, 01.01.23, 01.01.24, 12.01.13, 12.01.17, 01.01.30, 11.01.00, 25.00.13, 25.00.16, 25.00.19, 06.00.00, 05.02.06, 33.01.00, 05.02.16, 05.02.18, 33.00.06, 35.00.05, 35.00.10, 35.00.13, 33.00.20, 33.00.23, 33.00.24, 36.01.00, 36.00.06. 4. The built-in INDESIT firmware database contains 12943 firmwares. 2020/10/15 Sky Prog Programmer software Version 01.13 1. A completely new RS function has been added to the program. This function is intended for programming the entire flash memory of microcontrollers installed on electronic modules of the ARCADIA 2, ARCADIA 3, WINDY series of washing and dishwashers (at the moment). Supported controllers (at the time of the official release of the version): RENESAS R5F52Z05AAFM, RENESAS R5F52105AAFM, RENESAS R5F51305ADFM, RENESAS R5F51306ADFM SW (FW) are built into the program (at the time of the official release of the version): 11.01.13, 01.01.23, 01.01.24, 01.01.30, 12.01.13, 12.01.17, 25.00.13, 25.00.19, 33.00.20, 33.00.23, 33.00.24, 36.01.00 For more information, refer to the help built into the software or on the website. The RS feature was added and available in early September in version 01.12, and many have already started using it before the official release. The function was tested in parallel. 2. The INDESIT firmware database now contains 12926 firmware. 3. Added the function of copying to the clipboard the serial number, industrial code and product model from the "statistics" tab. 2020/04/01 Sky Prog Programmer software Version 01.12 1. Changed the display of error statistics for Indesit ARCADIA and WINDY. 2. Added function to display last error (last two errors) for ARCADIA and WINDY 3. Added new versions of WINDY: 33.00.20, 33.00.23. 4. The INDESIT firmware database now contains 12843 firmware. 5. Candy firmware database from 02/20/2019 replaced by the database from 11/25/2019. At the moment, this is the latest factory firmware database from Candy. 2019/12/01 Sky Prog Programmer software Version 01.11 1. Updated table for selecting firmware. 2. The INDESIT firmware database has been significantly updated. Now it contains 12837 firmware. 3. A new code has been added to the INDESIT firmware database for search, which was introduced by WHIRLPOOL engineers (starts at 400 ...) 2019/10/17 Sky Prog Programmer software Version 01.10 1. The function of working with the boards of ATLANT washing machines (series 1, 2, 4) has been expanded. Now you can see the error statistics, and also introduced the calculation of the checksum of the firmware. 2. Added a built-in database with firmware for ATLANT washing machines, series 1, 2, 4. 3. INDESIT firmware database now contains 10680 firmware. 2019/08/05 Sky Prog Programmer software Version 01.09 1. A new alert system has been introduced. 2. Added SW 360005. 3. INDESIT firmware database now contains 10669 firmware. If you did not find the desired firmware, please contact the author of the software. In this case, please provide the full serial number of the product. 4. The program lock is disabled in cases where the mysql database is not available on the server. 2019/03/25 Sky Prog Programmer software Version 01.08 1. Changed the structure of the software installation. Visually it is not noticeable. 2. Added SW 330020 3. INDESIT firmware database now contains 10662 firmware. 4. Configuration CANDY Plus is now completed with three databases of firmware. 5. Introduced the ability to switch in the Sky Prog software between several databases of CANDY firmware. 2019/02/03 Sky Prog Programmer software Version 01.07 1. Added the function to view the error statistics of washing machines with ARCADIA 3 modules. 2. When working with the Candy Invensys module, the auto-detect function of the microcontroller has been added. This can be the Atmega 32L or Atmega 644. So far, this only applies to modules that include a submodule with a separate 24C02 memory chip. 3. Base INDESIT firmware contains 10450 firmware. 4. Supported versions of ARCADIA 3: 010124, 010123, 010127, 110100, 110113, 010130, 250011, 250013, 250019 If you get a module with a different version, please contact the author of the program. 5. Implemented quick help system. These are windows with hints and tips designed to help novice users. 2018/04/21 Sky Prog Programmer software version 01.06 1. Added support for reading and programming ARCADIA 3, only through the tool on FT232RL chip (Elinv Prog). In current time SW versions (FW) 010127, 010130, 250011, 250013, 250019 are tested and supported. Error statistics are not yet available. 2. Now it's easier to reinstall the Sky Prog. After the software is uninstalled, the installation with the same key and the same place where the program was deleted is automatically launched (it is possible to cancel it for uninstall only). 3. Built-in database with firmware INDESIT updated and now contains more than 10,000 firmware! 4. Added the ability to sort the list of INDESIT firmware in the built-in database alphabetically. 2018/02/15 Sky Prog Programmer software version 01.05 1. Added checksum calculation for Candy MDL, Indesit EVO II, ARCADIA (configuration zone). Now you can find out for sure whether the firmware is working or not. 2. Expanded help when pressing F1. 3. SW firmware has been added to the Idesit database (only for versions with USBDM support). 4. Statistics for SW 010309 are added, but so far only in the testing phase. 5. The new USBDM software versions support now for USBDM recording. 6. For Indesit, a mapping table has been added to select the correct firmware. 7. Now possible to edit the serial number before program the firmware for Indesit. 8. It became possible to search for firmware in the built-in base of Indesit by a simple click on the code or model of the readed firmware. 9. Modified the read/write function EVO II through Elinv Prog/FT232RL. 10. When recording flash memory Indesit ARCADIA 1 the microcontroller version is now determined automatically (GB60 3L31R / GB60A 4L11Y). 11. Changed the organization of installation of the program and downloading from the server. In particular, now there is no need to download separately the base of the firmware. 12. Fixed minor identified bugs, the program is improved in various small things, fixed some text entries. In the near future in plan, work on reading / writing ARCADIA 3 (zone configuration), reading / writing EVO II via COM port, various add-ons to increase the convenience of working with the software Sky Prog. 2015/11/15 Version Skyprog Programmer CANDY LIGHT 01.03 and Sky Prog Programmer CANDY PLUS 01.03 What's new? Firstly, the program was divided into two areas. The first direction - as it was, the budget version, now has the additional title CANDY LITE. The second direction - added the module for parsing database of firmwares CANDY - "MEM BD Parser". The latest database to date (see. The date of the beginning), contains more than 10,000 firmwares. With this module, you can open any firmware into Candy Sky Prog Programmer or save it to disk as a single file. The program module MEM BD Parser received additional title CANDY PLUS. Now change the program. 1. Changed the view of the progress of read / write. Namely, the size, color, location. Added display of progress percent. I hope that everyone will like. 2. Added a status bar (at the bottom area of window). It contains information about the last operation - read, write, successful or not. 3. Fixed two typographical errors in the Russian text, which I found. Please tell me mistakes, if you find more !!! 4. Added checksum verification after recording via COM port of modules series Invensys. Previously, this was done only when recording through USB Elinv Prog. Now, if after recording the firmware appears window with the words "not converged control bytes", this recording is not performed correctly! It is necessary to ensure that the module is suitable for the model, if so, try more. Well, of course, make sure that the module is working. 5. Minimum and maximum limits on the number of bytes in the string when saving to a file of type * .HEX and * .TXT. Previously, this was not, and therefore can cause errors. 6. The panel displaying the contents of the firmware in the right zone - zone output ACSII characters, the so-called special characters are now replaced with semicolons, which was not in previous versions. This refinement led to the correct shown characters in this zone. 7. In the "About" added information about the program and about the key under the current working copy. 8. Added a tough test after recording module MDL using USB Elinv Prog. Previous verification was softer in the course of recording. 9. You can now drag and drop the firmware from computer from the external EEPROM 24C02 from INVENSYS module to display error statistics. 10. Added help. Only error codes MDL and INVENSYS modules of washing machines. Here, perhaps, everything. Huge please send your comments and suggestions to the address: promobr@mail.ru