Series 1,2,4
Error codes of ATLANT washing machines with INVENSYS electronic module with external memory 24C02, series 1, 2, 4
Error code |
Description |
SEL |
Program selector malfunction: the fault is detected if the selector is in the dead zone or contact is broken. |
F2 |
Malfunction of the temperature sensor (open circuit or short circuit): the error is determined when the signal from the sensor is outside the range corresponding to the temperatures (-20 …+120) С |
F3 |
Malfunction of the temperature sensor or heater: the error is determined if the temperature does not rise by 2 ° C for 15 minutes |
F4 |
Drain pump failure: the error is determined when the 3-minute timer has elapsed since the signal was sent to drain the water and the signal of the empty tank was reached from the level switch. |
F5 |
Malfunction of the water inlet system (damage to the level sensor or solenoid valve): the error is determined if, with the valve (or valves) turned on, the first level of the gulf is not reached — the signal from the level sensor-relay — within 10 minutes. |
F6 |
Malfunction of the water inlet system (damage to the level sensor or solenoid valve): the error is determined if, with the valve (or valves) turned on, the first level of the gulf is not reached — the signal from the level sensor-relay — within 10 minutes. |
F7 |
Network frequency violation: error is determined if the network frequency is out of range (44.5…65.5) Hz |
F8 |
Overflow fault (valve leakage): the error is detected when a special signal appears from the level sensor |
F9 |
Tachometer fault: the error is determined when the 3-second timer expires from the moment of setting and until the determination of speed other than 0 rpm. |
F10 |
Faulty door lock triac: to detect a malfunction, an input signal is used, which is consistent with the position of the triac of the door lock:
|
door |
Door lock fault: the error is determined when the 5-second timer has elapsed since the signal was sent to close the lock. |
F12 |
Tachometer fault: the error is determined when the 3-second timer expires from the moment of setting and until the determination of speed other than 0 rpm. |
F13 |
EEPROM fault: when reading phases with E²PROM, the checksum is calculated and compared with the specified checksum. A failure is determined if the two checksums are different. |
F14 |
I2C Line Fault: the fault is determined if requests are not completed when accessing via I2C. For LCD versions, the problem is determined if no I2C request is processed correctly. |