EVO II
Error codes for washing machines Indesit / Ariston / Hotpoint with electronic module EVO II
Code |
Description, possible reasons |
F01 |
Short-circuit triac of drive motor control |
F02 |
The tachogenerator does not generate a signal about the rotation of the drive motor (the sensor circuit may be in the clipping or short-circuited). Другой причиной этой ошибки является блокировка приводного двигателя. |
F03 |
Temperature sensor circuit (NTC) in the open or short circuit. The port of the NTC control panel is defective. |
F04 |
The level sensor (pressostat) simultaneously generates the signals "EMPTY TANK" and "OVERFLOW" |
F05 |
After the discharge program is executed, the level sensor does not form the "BLANK TANK" signal (the drain pump is not working, the drainage path is blocked, the level sensor is faulty) |
F06 |
The program code is not recognized (error of buttons on the front panel) |
F07 |
There is no heating |
F08 |
"Clogging" the contact group of the heater relay. Defective heater or its wiring (leakage to the housing) |
F09 |
Error (crash) of contents of non-volatile EEPROM memory |
F10 |
Simultaneous absence of signals from the level sensor FULL TANK and EMPTY TANK |
F11 |
There is no supply voltage at the drain pump (pump supply circuit in the open circuit) |
F12 |
There is no communication between the display module and the electronic controller |
F13 |
Drying temperature sensor circuit in the open or short circuit |
F14 |
The drying heater does not work (only for washing machines with drying) |
F15 |
Faulty drying heater relay (only for washing machines with drying) |
F16 |
Blocked drum (only in washing with top loading) |
F17 |
The door lock is not energized or the door is open |
F18 |
Communication error between the controller ICs and the DSP (Asynchronous Drive Motor Control Processor) on the main board |