C
o
o
k
i
n
g
HOTTIMA 2010 (Full) Fault Table
FAULT SUBCODE DESCRIPTION CHECK S
F12
01 Communication- MAIN
1 Unplug, wait for 2 minutes, plug back in again and
test the appliance.
2 Reprogram the Main PCB.
3 Replace the Main PCB.
4 Replace the Display PCB.
02 Communication - VISUAL
03
C o m m u n i c a t i o n - N O
A L I G N M E N T W I T H M A I N
SETTING (ON BOARD SETTING
OK (CHKSUM OK))
04
C o m m u n i c a t i o n - N O
A L I G N M E N T W I T H M A I N
SETTING + ON BOARD SETTING
CORRUPTED (CHKSUM KO))
F13 01
F l o o r h e a t i n g e l e m e n t : D I
S C O N N E C T E D o r
INTERRUPTED / heating element
relay jammed / heating element
dispersing energy, master relay
jammed.
1 Check that the floor heating element is working
properly.
2 Check connectors on component and board sides.
3 Check the state of cables.
4 Replace the Main PCB.
F14 01
Circular heating element D
I S C O N N E C T E D o r
INTERRUPTED / heating element
relay jammed / heating element
dispersing energy, master relay
jammed.
1 Check that the circular heating element is working
properly.
2 Check connectors on component and board sides.
3 Check the state of cables.
4 Replace the Main PCB.
F16 01
S t e a m h e a t i n g e l e m e n t : D I
S C O N N E C T E D o r
INTERRUPTED / heating element
relay jammed / heating element
dispersing energy, master relay
jammed.
1 Check that the steam heating element is working
properly.
2 Check connectors on component and board sides.
3 Check the state of cables.
4 Replace the Main PCB.
F17 01
G r i l l 1 h e a t i n g e l e m e n t : D I
S C O N N E C T E D o r
INTERRUPTED / heating element
relay jammed / heating element
dispersing energy, master relay
jammed.
1 Check that the Grill 1 heating element is working
properly.
2 Check connectors on component and board sides.
3 Check the state of cables.
4 Replace the Main PCB.
F18 01
Grill 2 heating element: D
I S C O N N E C T E D o r
INTERRUPTED / heating element
relay jammed / heating element
dispersing energy, master relay
jammed.
1 Check that the Grill 2 heating element is working
properly.
2 Check connectors on component and board sides.
3 Check the state of cables.
4 Replace the Main PCB.
F19 01
Divider heating element: D
I S C O N N E C T E D o r
INTERRUPTED / heating element
relay jammed / heating element
dispersing energy, master relay
jammed.
1 Check that the divider heating element is working
properly.
2 Check connectors on component and board sides.
3 Check the state of cables.
4 Replace the Main PCB.
F20 01
Ceiling heating element: D
I S C O N N E C T E D o r
INTERRUPTED / heating element
relay jammed / heating element
dispersing energy, master relay
jammed.
1 Check that the ceiling heating element is working
properly.
2 Check connectors on component and board sides.
3 Check the state of cables.
4 Replace the Main PCB.
F22 01
A heating element is dispersing
energy (not possible to indicate
which) or master relay jammed.
1 Check if any of the heating elements are
dispersing
energy.
2 Replace the Main PCB.
3 / 4